Waukesha Cherry-Burrell Products: Universal II Series Rectangular Flange
PD Pumps - Model 214-UII

0-600 RPM speed range. 4" (101.6 mm) discharge port size; suitable to 500 PSI (34.5 bar) differential pressure. Temperature range -40°F (-40°C) to 300°F (149°C)

NOTE:
Contact Application Engineering for higher pressure or higher temperature applications. For higher pressures, refer to WCB Universal II Series Pumps and WCB Pump Notes, PN 12-99.

 
A
AA
AOL
B
CP
CP1
CP4
DL
E
F
H
I
J
L
U
X
2X
IN
18.00
4.38
35.94
12.00
27.08
28.58
-
27.13
.75
9.50
.69
16.86
5.06
21.26
2.375
8.81
16.17
MM
457
111
913
305
688
726
-
689
19
241
18
428
129
540
60.33
224
411

 
C
CA
CB
CC
FA
FB
HA
PA
PB
PC
PD
IN
.75
7.50
16.5
.75
9.00
18.00
.69
3.45
12.70
2.78
2.65
MM
21
203
419
19
229
457
18
88
323
71
67

CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection sizes for Jacketed Covers are ¾"-14 NPT on Models 014-UII to 034-UII, 1"-11-½ NPT on Models 064-UII and 134-UII.

Dimension 'X' and '2X' apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.

NOTE: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed.

Approximate shipping weight 933 lb. (423 kg.) pump only.


Pump Curve 95-07158 for Model 214-UII (in pdf format, 184KB)

Note: Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.

Instructions and Guidelines for Reading and Understanding Waukesha Cherry-Burrell PD Pump Curves (in pdf format, 509KB)

Back to Rectangular Flange Series Universal II Pumps

Product Literature:

 

Site Map | SPX Corporation | SPX Process Equipment | SPX Flow Control